Electrical supply

Electrical connected load ratings

 

 

6.10

10.10

3~ 200 V 50/60 Hz (3/PE)

 

 

 

Rated power consumption

[kW]

10.5

18.9

Convection power

[kW]

10.5 @200V

18.9 @200V

Motor power

[kW]

0.35

0.35

Rated current

[A]

30.3

54.6

Fuse rating

[A]

35

63

Protective earth current

[mA]

6.6

6.6

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length

[mm2]

4G6

4G16

Recommended residual-current device

Type

A

A

Optional residual-current device

Type

B

B

3~ 220-240V 50/60Hz (3/PE)

 

 

 

Rated power consumption

[kW]

9.6 - 11.3

17.2 - 20.4

Convection power

[kW]

10.5 @230V

18.9 @230V

Motor power

[kW]

0.35

0.35

Rated current

[A]

25.2 - 27.2

45.1 - 49.1

Fuse rating

[A]

35

50

Protective earth current

[mA]

6.6

6.6

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length

[mm2]

4G6

4G10

Recommended residual-current device

Type

A

A

Optional residual-current device

Type

B

B

3N~ 380-415V 50/60Hz (3/N/PE)

 

 

 

Rated power consumption

[kW]

9.6 - 11.3

17.2 - 20.4

Convection power

[kW]

10.5 @230V

18.9 @230V

Motor power

[kW]

0.35

0.35

Rated current

[A]

14.6 - 15.7

26.1 - 28.4

Fuse rating

[A]

16

32

Protective earth current

[mA]

6.14

6.14

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length

[mm2]

5G4

5G6

Recommended residual-current device

Type

A

A

Optional residual-current device

Type

B

B


Up