Not enough water in the boiler (water level could not be reached within 3 minutes, or 1 minute in start-up mode)
Possible reason for fault |
Corrective action |
---|---|
Soft water connection not connected to the water supply |
Connect the soft water connection to the water supply |
Water supply is shut off |
Open the soft water supply |
Water filter connection is not connected to the water connection |
The inlet or outlet of the water filter must be connected and screwed open |
The appliance was not connected to the soft water supply and the supply line has limescale build-up due to high water hardness |
Connect the water filter upstream of the soft water inlet and descale the soft water line. |
Water conductivity too low because of water softening (min. 20 µS/cm). The water level cannot be determined due to the lack of a water conductivity value |
The quality of the connected water must be brought into the range of the specification Link |