E22.3.1.x - CTC fault

Product line: mini, maxx, maxx pro

Description

Error from core temperature probe (third measurement point CTC3),
broken probe, open-circuit

Error correction

Possible reason for fault

Corrective action

CTC probe bent or broken

Contact the responsible service partner (make a note of the message on the display)

CTC probe cable insulation damaged

Contact the responsible service partner (make a note of the message on the display)


Up