E23.3.x.x - Boiler heater overtemperature

Product line: maxx pro

Description

Boiler sensor (-4B4 thermocouple)
overtemperature (if temperature in boiler is measured at above 130 °C for longer than 5 sec.)

Error correction

Possible reason for fault

Corrective action

Foaming in the boiler during cooking due to the use of a non-original Convotherm cleaning agent that has a strong tendency to foam

 

Use original Convotherm cleaning agent

High salt / mineral content of water

Use suitable water filter

Water very soft and still too many minerals in the water (check water hardness proportionally to conductivity)

Use suitable water filter