Gas type |
|
Natural gas 2H (E) |
Natural gas 2L (LL) |
Propane 3P |
Liquefied gas 3B/P |
|
Standard test gas, code |
|
G20 |
G25 |
G31 |
G30/G31 |
|
Operating materials |
||||||
Natural gas, liquid gas |
|
x |
x |
x |
x |
|
Gas supply values |
||||||
Gas pipe connection |
|
R 3/4" |
R 3/4" |
R 3/4" |
R 3/4" |
|
Supply flow pressure |
[mbar] |
20 (17 - 25) |
20/25 (18 - 30) |
29/37/50 (25 - 57.5) |
29/37/50 (25 - 57.5) |
|
Gas data (as per CE) at 15 °C and 1013 mbar dry |
||||||
Lower Wobbe Index Wi |
[MJ/m3] |
45.7 |
37.4 |
70.7 |
80.6 |
|
Upper Wobbe Index WS |
[MJ/m3] |
50.7 |
41.5 |
76.8 |
87.3 |
|
Lower calorific value Hi |
[MJ/m3] |
34 |
29.3 |
88 |
116.1 |
|
|
[MJ/kg] |
- |
- |
46.3 |
45.7 |
|
Higher calorific value HS |
[MJ/m3] |
37.8 |
32.5 |
95.7 |
125.8 |
|
|
[MJ/kg] |
- |
- |
50.4 |
49.5 |
|
Exhaust gas extraction system |
||||||
Air ventilation system with safety shutdown |
|
mandatory |
mandatory |
mandatory |
mandatory |
|
Exhaust gas values |
||||||
CO2 |
[%] |
9.3 - 9.5 |
9.1 - 9.3 |
10.8 - 11.2 |
12.8 - 13.3 |
|
CO |
[ppm] |
< 500 |
< 500 |
< 500 |
< 500 |