Replacing the cleaning agent canister

For your safety when using the combi oven

Before starting work, it is essential that you familiarize yourself with the information provided in the chapter 'For your safety' on this service page and the rules and hazard warnings in this instruction manual, and follow the instructions provided.

Materials required

Replacing the cleaning agent canister (table-top units)

1.

Specific Graphics Template

Risk of chemical burns or irritation to skin, eyes and respiratory system

  • Do not let the cleaning agents come into contact with skin, eyes or mucous membranes.
  • Do not inhale vapours from the cleaning agent.
  • Wear personal protective equipment.

Remove the seal on the replacement canister for the ConvoClean new or ConvoClean forte cleaning agent.

2.

  • Locate the canister that is connected by the (red) tube to the cleaning agent connector (G) underneath the appliance on the left-hand side.
  • Unscrew the (red) supply tube (2) plus suction nozzle from the located canister.
  • Remove the empty cleaning agent canister.

3.

  • Place ready the new canister (1) filled with cleaning agent.
  • Feed the (red) supply tube plus suction nozzle (2) into the full canister (1) and screw it on.
  • Make sure that there are no kinks in the tube and that the vent hole on the canister cap is unobstructed.

4.

  • Check the position of the canisters:
    • The surface on which the canisters sit must not lie above the level at which the appliance feet meet the appliance case.
    • The surface on which the canisters sit must not lie more than 1 metre below this level.

 

  • Check that you have connected the tube to the correct connector.
    • The cleaning agent must be attached to appliance connector G.

      (The colour red is used throughout.)

 