Electrical supply
Electrical supply

 

 

6.06 mini

6.10 mini

10.10 mini

3N~ 400V 50/60Hz (3/N/PE)

 

 

 

Rated power consumption

[kW]

5.7

7.1

10.5

Convection power

[kW]

5.4

6.8

10.2

Motor power

[kW]

0.25

0.25

0.25

Rated current

[A]

11.8

14.8

15.7

Fuse rating

[A]

16

16

20

Protective earth current (leakage current, with reduced fan speed)

[mA]

7

7

7

Protective earth current (leakage current, with fan speed not reduced)

[mA]

2

2

2

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G2.5

5G2.5

5G2.5

3~ 200V 50/60Hz (3/PE)

 

 

 

Rated power consumption

[kW]

5.7

7.1

10.5

Convection power

[kW]

5.4

6.8

10.2

Motor power

[kW]

0.25

0.25

0.25

Rated current

[A]

17.1

21.1

31.0

Fuse rating

[A]

20

25

35

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G4

4G4

4G4

3~ 230V 50/60Hz (3/PE)

 

 

 

Rated power consumption

[kW]

5.7

7.1

10.5

Convection power

[kW]

5.4

6.8

10.2

Motor power

[kW]

0.25

0.25

0.25

Rated current

[A]

23.5

28.5

26.5

Fuse rating

[A]

25

35

32

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G4

4G4

4G4


Up