6.06 mini |
6.10 mini |
10.10 mini |
---|---|---|---|---|
3~ 400V 50/60Hz (3/PE) |
|
|
|
|
Rated power consumption |
[kW] |
5.7 |
7.1 |
10.5 |
Convection power |
[kW] |
5.4 |
6.8 |
10.2 |
Motor power |
[kW] |
0.25 |
0.25 |
0.25 |
Rated current |
[A] |
8.7 |
10.7 |
15.7 |
Fuse rating |
[A] |
16 |
16 |
20 |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G2.5 |
5G2.5 |
5G2.5 |
3~ 440V 60Hz (3/PE) |
|
|
|
|
Rated power consumption |
[kW] |
5.7 |
7.1 |
10.5 |
Convection power |
[kW] |
5.4 |
6.8 |
10.2 |
Motor power |
[kW] |
0.25 |
0.25 |
0.25 |
Rated current |
[A] |
13 |
9.6 |
14.1 |
Fuse rating |
[A] |
16 |
16 |
20 |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G2.5 |
5G2.5 |
5G2.5 |
3~ 480V 60Hz (3/PE) |
|
|
|
|
Rated power consumption |
[kW] |
6.7 |
8.4 |
12.4 |
Convection power |
[kW] |
6.4 |
8.1 |
12.1 |
Motor power |
[kW] |
0.25 |
0.25 |
0.25 |
Rated current |
[A] |
13.9 |
10.3 |
15.2 |
Fuse rating |
[A] |
16 |
16 |
20 |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G2.5 |
5G2.5 |
5G2.5 |