Product line: mini,maxx,maxx pro
Topic: Not sealed
Water dripping out of the front area of the appliance floor on table-top units

| Possible reason for fault | Corrective action | 
|---|---|
| Hygienic plug-in gasket worn | Replace the hygienic plug-in gasket | 
| Hygienic plug-in gasket installed backwards – sealing surface swapped with gasket base | Install the hygienic plug-in gasket correctly | 
| Drain connection blocked | Clean the drain connection | 