Product line: mini,maxx,maxx pro
Topic: Not sealed
Water dripping out of the door area

| Possible reason for fault | Corrective action | 
|---|---|
| Interior glass pane very dirty | Clean the interior glass pane, especially the sealing surfaces of the interior glass pane | 
| Interior glass pane installed incorrectly | 
 | 
| Hygienic plug-in gasket worn | Replace the hygienic plug-in gasket | 
| CTC probe cable is crushed between the hygienic plug-in gasket and the interior glass pane | Lay the cable so that it remains inside the cooking chamber | 