Product line: mini,maxx,maxx pro
Topic: Cooking chamber
Uneven browning
Possible reason for fault |
Corrective action |
---|---|
Not preheated enough |
Use preheat time, extend preheat time |
Suction panel not fitted correctly |
Check the installation of the suction panel as to whether all attachment points are seated correctly and closed Link |
Hygienic plug-in gasket worn |
Replace the hygienic plug-in gasket |
Uneven loading |
Distribute the load evenly in the cooking chamber, i.e. starting from the centre, distribute it evenly over the entire cooking chamber and ensure adequate air circulation by providing enough air space between the food containers. |