Water connection

C4 EB/ES/GB/GS (table-top units)

Water supply (cold only)

 

 

Water supply

 

2 x G 3/4'' fixed connection, optionally including connecting pipe (min. DN13 / 1/2'')

Flow pressure

[kPa]

150 - 600 (1.5 - 6 bar)

Pressure gauge in the water supply

[kPa]

100 (1 bar)

Water drain

 

 

Model

 

Funnel drain with P-trap (recommended) or fixed connection

Type

DN

50

Waste water temperature

[°C]

max. 80

Slope for drain pipe

 

min. 3.5% (2°)

Safety overflow

[mm]

80 x 25 mm

C4 EB/ES/GB/GS (table-top units, United Kingdom)

Water supply (cold only)

 

 

Shut-off device

 

With double check valve (type BA or CA) and dirt filter

Water supply

 

2 x G 3/4'' fixed connection, optionally including connecting pipe (min. DN13 / 1/2'')

Flow pressure

[kPa]

150 - 600 (1.5 - 6 bar)

Pressure gauge in the water supply

[kPa]

100 (1 bar)

Water drain

 

 

Model

 

Funnel drain with P-trap (recommended) or fixed connection

Type

DN

50

Waste water temperature

[°C]

max. 80

Slope for drain pipe

 

min. 3.5% (2°)

Safety overflow

[mm]

80 x 25 mm

C4 EB/ES/GB/GS (floor-standing units)

Water supply (cold only)

 

 

Shut-off device

 

With EA (verifiable) check valve and dirt filter

Water supply

 

2 x G 3/4'' fixed connection, optionally including connecting pipe (min. DN13 / 1/2'')

Flow pressure

[kPa]

150 - 600 (1.5 - 6 bar)

Pressure gauge in the water supply

[kPa]

150 (1.5 bar)

Water drain

 

 

Model

 

Fixed connection (recommended) or open tank or channel/gully

Type

DN

50

Waste water temperature

[°C]

max. 80

Slope for drain pipe

 

min. 3.5% (2°)

Safety overflow

[mm]

80 x 25 mm

C4 EB/ES/GB/GS (floor-standing units, United Kingdom)

Water supply (cold only)

 

 

Shut-off device

 

With double check valve (type BA or CA) and dirt filter

Water supply

 

2 x G 3/4'' fixed connection, optionally including connecting pipe (min. DN13 / 1/2'')

Flow pressure

[kPa]

150 - 600 (1.5 - 6 bar)

Pressure gauge in the water supply

[kPa]

150 (1.5 bar)

Water drain

 

 

Model

 

Fixed connection (recommended) or open tank or channel/gully

Type

DN

50

Waste water temperature

[°C]

max. 80

Slope for drain pipe

 

min. 3.5% (2°)

Safety overflow

[mm]

80 x 25 mm


Up