Electrical supply, EB/ES
Contents

C4 EB/ES

C4 EB/ES (single-phase FC)

C4 EB/ES

 

 

6.10

6.20

10.10

10.20

3~ 400 V 50/60 Hz

 

 

 

 

Rated power consumption

[kW]

11.0

19.5

19.5

33.7

Rated power consumption with Smoker

[kW]

11.3

-

-

-

Convection power

[kW]

10.5

18.9

18.9

33.0

Steam power (EB only)

[kW]

9.0

18.0

18.0

27.0

Rated current

[A]

15.9

28.1

28.1

48.7

Rated current with Smoker

[A]

16.6

-

-

-

Fuse rating

[A]

16

35

35

50

Fuse rating with Smoker

[A]

20

-

-

-

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G4

5G6

5G6

5G16

Residual-current device

Type

B

B

B

B

C4 EB/ES (single-phase FC)

 

 

6.10

6.20

10.10

10.20

3N~ 400V 50/60Hz (3/N/PE)

 

 

 

 

Rated power consumption

[kW]

11.0

19.5

19.5

33.7

Rated power consumption with Smoker

[kW]

11.3

-

19.8

-

Convection power

[kW]

10.5

18.9

18.9

33.0

Steam power (EB only)

[kW]

9.0

18.0

18.0

27.0

Rated current

[A]

15.9

28.1

28.1

48.7

Rated current with Smoker

[A]

17.1

-

-

-

Fuse rating

[A]

16

32

32

50

Fuse rating with Smoker

[A]

20

-

-

-

Residual current

[mA]

~7.5

~7.5

~7.5

~7.5

Protective earth current

[mA]

~7.5

~7.5

~7.5

~7.5

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G4

5G6

5G6

5G16

Residual-current device

Type

A/B

A/B

A/B

A/B

3~ 230V 50/60Hz (3/PE)

 

 

 

 

Rated power consumption

[kW]

10.9

19.3

19.3

33.4

Convection power

[kW]

10.5

18.9

18.9

33.0

Steam power (EB only)

[kW]

9.0

18.0

18.0

27.0

Rated current

[A]

27.4

48.5

48.5

84.0

Fuse rating

[A]

35

50

50

100

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G6

4G16

4G16

4G35

Residual-current device

Type

A/B

A/B

A/B

A/B


Up