Electrical supply, EB/ES
Contents

C4 EB/ES

C4 EB/ES

 

 

20.10

20.20

3N~ 400V 50/60Hz (3/N/PE)

 

 

Rated power consumption

[kW]

38.9

67.3

Convection power

[kW]

37.8

66.0

Steam power (EB only)

[kW]

27.0

39.9

Rated current

[A]

56.2

97.3

Fuse rating

[A]

63

100

Residual current

[mA]

~16.5

~16.5

Protective earth current

[mA]

~16.5

~16.5

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length

[mm2]

5G16

5G35

Residual-current device

Type

A/B

A/B

3~ 230V 50/60Hz (3/PE)

 

 

Rated power consumption

[kW]

38.2

66.4

Convection power

[kW]

37.8

66.0

Steam power (EB only)

[kW]

27.0

39.9

Rated current

[A]

96.0

166.9

Fuse rating

[A]

100

200

Residual current

[mA]

-

-

Protective earth current

[mA]

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length

[mm2]

4G35

4G70

Residual-current device

Type

A/B

A/B


Up