Contents |
|
|
20.10 |
20.20 |
3~ 400 V 50/60 Hz |
|
|
|
Rated power consumption |
[kW] |
38.9 |
67.3 |
Convection power |
[kW] |
37.8 |
66.0 |
Steam power (EB only) |
[kW] |
27.0 |
39.9 |
Rated current |
[A] |
56.2 |
97.3 |
Fuse rating |
[A] |
63 |
100 |
Residual current |
[mA] |
- |
- |
Protective earth current |
[mA] |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length |
[mm2] |
5G16 |
5G35 |
Residual-current device |
Type |
B |
B |
3~ 440V 50/60Hz |
|
|
|
Rated power consumption |
[kW] |
32.6 |
56.3 |
Convection power |
[kW] |
31.8 |
55.4 |
Steam power (EB only) |
[kW] |
22.7 |
33.5 |
Rated current |
[A] |
42.8 |
73.9 |
Fuse rating |
[A] |
50 |
100 |
Residual current |
[mA] |
- |
- |
Protective earth current |
[mA] |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G16 |
4G35 |
Residual-current device |
Type |
B |
B |
3~ 480V 50/60Hz |
|
|
|
Rated power consumption |
[kW] |
38.6 |
66.8 |
Convection power |
[kW] |
37.8 |
66.0 |
Steam power (EB only) |
[kW] |
27.0 |
39.9 |
Rated current |
[A] |
46.5 |
80.5 |
Fuse rating |
[A] |
50 |
100 |
Residual current |
[mA] |
- |
- |
Protective earth current |
[mA] |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G16 |
4G35 |
Residual-current device |
Type |
B |