Electrical supply, marine
Contents

C4 EB/ES

C4 EB/ES

 

 

20.10

20.20

3~ 400 V 50/60 Hz

 

 

Rated power consumption

[kW]

38.9

67.3

Convection power

[kW]

37.8

66.0

Steam power (EB only)

[kW]

27.0

39.9

Rated current

[A]

56.2

97.3

Fuse rating

[A]

63

100

Residual current

[mA]

-

-

Protective earth current

[mA]

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length

[mm2]

5G16

5G35

Residual-current device

Type

B

B

3~ 440V 50/60Hz

 

 

Rated power consumption

[kW]

32.6

56.3

Convection power

[kW]

31.8

55.4

Steam power (EB only)

[kW]

22.7

33.5

Rated current

[A]

42.8

73.9

Fuse rating

[A]

50

100

Residual current

[mA]

-

-

Protective earth current

[mA]

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G16

4G35

Residual-current device

Type

B

B

3~ 480V 50/60Hz

 

 

Rated power consumption

[kW]

38.6

66.8

Convection power

[kW]

37.8

66.0

Steam power (EB only)

[kW]

27.0

39.9

Rated current

[A]

46.5

80.5

Fuse rating

[A]

50

100

Residual current

[mA]

-

-

Protective earth current

[mA]

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G16

4G35

Residual-current device

Type

B

B