Contents |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
---|---|---|---|---|---|
3~ 400 V 50/60 Hz |
|
|
|
|
|
Rated power consumption |
[kW] |
11.0 |
19.5 |
19.5 |
33.7 |
Convection power |
[kW] |
10.6 |
19.1 |
19.1 |
33.3 |
Steam power |
[kW] |
9.1 |
18.1 |
18.1 |
27.2 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
15.9 |
28.1 |
28.1 |
48.7 |
Fuse rating |
[A] |
16 |
35 |
35 |
50 |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G4 |
5G6 |
5G6 |
5G16 |
Residual-current device |
Type |
B |
B |
B |
B |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
---|---|---|---|---|---|
3~ 400 V 50/60 Hz |
|
|
|
|
|
Rated power consumption |
[kW] |
11.0 |
19.5 |
19.5 |
33.7 |
Convection power |
[kW] |
10.6 |
19.1 |
19.1 |
33.3 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
15.9 |
28.1 |
28.1 |
48.7 |
Fuse rating |
[A] |
16 |
35 |
35 |
50 |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G4 |
5G6 |
5G6 |
5G16 |
Residual-current device |
Type |
B |
B |
B |
B |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
---|---|---|---|---|---|
3~ 400 V 50/60 Hz |
|
|
|
|
|
Rated power consumption |
[kW] |
11.0 |
19.5 |
19.5 |
33.7 |
Rated power consumption with Smoker |
[kW] |
11.3 |
- |
- |
- |
Convection power |
[kW] |
10.6 |
19.1 |
19.1 |
33.3 |
Steam power |
[kW] |
9.1 |
18.1 |
18.1 |
27.2 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
15.9 |
28.1 |
28.1 |
48.7 |
Rated current with Smoker |
[A] |
16.6 |
- |
- |
- |
Fuse rating |
[A] |
16 |
35 |
35 |
50 |
Fuse protection with Smoker |
[A] |
20 |
- |
- |
- |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G4 |
5G6 |
5G6 |
5G16 |
Residual-current device |
Type |
B |
B |
B |
B |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
---|---|---|---|---|---|
3~ 400 V 50/60 Hz |
|
|
|
|
|
Rated power consumption |
[kW] |
11.0 |
19.5 |
19.5 |
33.7 |
Rated power consumption with Smoker |
[kW] |
11.3 |
- |
- |
- |
Convection power |
[kW] |
10.6 |
19.1 |
19.1 |
33.3 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
15.9 |
28.1 |
28.1 |
48.7 |
Rated current with Smoker |
[A] |
16.6 |
- |
- |
- |
Fuse rating |
[A] |
16 |
35 |
35 |
50 |
Fuse protection with Smoker |
[A] |
20 |
- |
- |
- |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G4 |
5G6 |
5G6 |
5G16 |
Residual-current device |
Type |
B |
B |
B |
B |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
---|---|---|---|---|---|
3N~ 400V 50/60Hz (3/N/PE) |
|
|
|
|
|
Rated power consumption |
[kW] |
11.0 |
19.5 |
19.5 |
33.7 |
Rated power consumption with Smoker |
[kW] |
11.3 |
- |
19.8 |
- |
Convection power |
[kW] |
10.6 |
19.1 |
19.1 |
33.3 |
Steam power |
[kW] |
9.1 |
18.1 |
18.1 |
27.2 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
15.9 |
28.1 |
28.1 |
48.7 |
Rated current with Smoker |
[A] |
17.1 |
- |
- |
- |
Fuse rating |
[A] |
16 |
32 |
32 |
50 |
Fuse protection with Smoker |
[A] |
20 |
- |
- |
- |
Residual current |
[mA] |
~7.5 |
~7.5 |
~7.5 |
~7.5 |
Protective earth current |
[mA] |
~7.5 |
~7.5 |
~7.5 |
~7.5 |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G4 |
5G6 |
5G6 |
5G16 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
A/B |
3~ 230V 50/60Hz (3/PE) |
|
|
|
|
|
Rated power consumption |
[kW] |
10.9 |
19.3 |
19.3 |
33.4 |
Convection power |
[kW] |
10.5 |
18.9 |
18.9 |
33.0 |
Steam power |
[kW] |
9.0 |
18.0 |
18.0 |
27.0 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
27.4 |
48.5 |
48.5 |
84.0 |
Fuse rating |
[A] |
35 |
50 |
50 |
100 |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G6 |
4G16 |
4G16 |
4G35 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
A/B |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
---|---|---|---|---|---|
3N~ 400V 50/60Hz (3/N/PE) |
|
|
|
|
|
Rated power consumption |
[kW] |
11.0 |
19.5 |
19.5 |
33.7 |
Rated power consumption with Smoker |
[kW] |
11.3 |
- |
19.8 |
- |
Convection power |
[kW] |
10.6 |
19.1 |
19.1 |
33.3 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
15.9 |
28.1 |
28.1 |
48.7 |
Rated current with Smoker |
[A] |
17.1 |
- |
- |
- |
Fuse rating |
[A] |
16 |
32 |
32 |
50 |
Fuse protection with Smoker |
[A] |
20 |
- |
- |
- |
Residual current |
[mA] |
~7.5 |
~7.5 |
~7.5 |
~7.5 |
Protective earth current |
[mA] |
~7.5 |
~7.5 |
~7.5 |
~7.5 |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G4 |
5G6 |
5G6 |
5G16 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
A/B |
3~ 230V 50/60Hz (3/PE) |
|
|
|
|
|
Rated power consumption |
[kW] |
10.9 |
19.3 |
19.3 |
33.4 |
Convection power |
[kW] |
10.5 |
18.9 |
18.9 |
33.0 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
27.4 |
48.5 |
48.5 |
84.0 |
Fuse rating |
[A] |
35 |
50 |
50 |
100 |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G6 |
4G16 |
4G16 |
4G35 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
A/B |