Electrical supply, GB/GS
Contents

C4 GB (single-phase FC)

C4 GS (single-phase FC)

C4 GB (single-phase FC)

 

 

6.10

6.20

10.10

10.20

1N~ 230V 50/60Hz (1/N/PE)

 

 

 

 

Rated power consumption

[kW]

0.6

0.6

0.6

0.6

Convection power

[kW]

0.1

0.1

0.1

0.1

Steam power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

2.7

2.7

2.7

2.7

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

7.9

-

7.5

-

Protective earth current

[mA]

28.0

-

14.3

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B

C4 GS (single-phase FC)

 

 

6.10

6.20

10.10

10.20

1N~ 230V 50/60Hz (1/N/PE)

 

 

 

 

Rated power consumption

[kW]

0.6

0.6

0.6

0.6

Convection power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

2.7

2.7

2.7

2.7

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

7.0

7.0

6.9

-

Protective earth current

[mA]

28.0

33.0

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B


Up