Contents |
|
|
12.20 |
20.10 |
20.20 |
3~ 400V 50/60Hz |
|
|
|
|
Rated power consumption |
[kW] |
33.7 |
38.9 |
67.3 |
Convection power |
[kW] |
33.3 |
38.1 |
66.5 |
Steam power |
[kW] |
31.6 |
31.6 |
40.2 |
Motor power |
[kW] |
0.35 |
0.7 |
0.7 |
Rated current |
[A] |
48.7 |
56.2 |
97.3 |
Fuse rating |
[A] |
50 |
63 |
100 |
Residual current |
[mA] |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G16 |
5G16 |
5G35 |
Residual-current device |
Type |
B |
B |
B |
|
|
12.20 |
20.10 |
20.20 |
3~ 400V 50/60Hz |
|
|
|
|
Rated power consumption |
[kW] |
33.7 |
38.9 |
67.3 |
Convection power |
[kW] |
33.3 |
38.1 |
66.5 |
Motor power |
[kW] |
0.35 |
0.7 |
0.7 |
Rated current |
[A] |
48.7 |
56.2 |
97.3 |
Fuse rating |
[A] |
50 |
63 |
100 |
Residual current |
[mA] |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G16 |
5G16 |
5G35 |
Residual-current device |
Type |
B |
B |
B |
|
|
12.20 |
20.10 |
20.20 |
3N~ 400V 50/60Hz (3/N/PE) |
|
|
|
|
Rated power consumption |
[kW] |
33.7 |
38.9 |
67.3 |
Convection power |
[kW] |
33.3 |
38.1 |
66.5 |
Steam power |
[kW] |
31.6 |
31.6 |
40.2 |
Motor power |
[kW] |
0.35 |
0.7 |
0.7 |
Rated current |
[A] |
48.7 |
56.2 |
97.3 |
Fuse rating |
[A] |
50 |
63 |
100 |
Residual current |
[mA] |
~7.5 |
~16.5 |
~16.5 |
Protective earth current |
[mA] |
~7.5 |
~16.5 |
~16.5 |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G16 |
5G16 |
5G35 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
3~ 230V 50/60Hz (3/PE) |
|
|
|
|
Rated power consumption |
[kW] |
33.4 |
38.2 |
66.4 |
Convection power |
[kW] |
33.0 |
37.8 |
66.0 |
Steam power |
[kW] |
31.3 |
31.3 |
39.9 |
Motor power |
[kW] |
0.35 |
0.7 |
0.7 |
Rated current |
[A] |
84.0 |
96.0 |
166.9 |
Fuse rating |
[A] |
100 |
100 |
200 |
Residual current |
[mA] |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G35 |
4G35 |
4G70 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
|
|
12.20 |
20.10 |
20.20 |
3N~ 400V 50/60Hz (3/N/PE) |
|
|
|
|
Rated power consumption |
[kW] |
33.7 |
38.9 |
67.3 |
Convection power |
[kW] |
33.3 |
38.1 |
66.5 |
Motor power |
[kW] |
0.35 |
0.7 |
0.7 |
Rated current |
[A] |
48.7 |
56.2 |
97.3 |
Fuse rating |
[A] |
50 |
63 |
100 |
Residual current |
[mA] |
~7.5 |
~16.5 |
~16.5 |
Protective earth current |
[mA] |
~7.5 |
~16.5 |
~16.5 |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
5G16 |
5G16 |
5G35 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
3~ 230V 50/60Hz (3/PE) |
|
|
|
|
Rated power consumption |
[kW] |
33.4 |
38.2 |
66.4 |
Convection power |
[kW] |
33.0 |
37.8 |
66.0 |
Motor power |
[kW] |
0.35 |
0.7 |
0.7 |
Rated current |
[A] |
84.0 |
96.0 |
166.9 |
Fuse rating |
[A] |
100 |
100 |
200 |
Residual current |
[mA] |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G35 |
4G35 |
4G70 |
Residual-current device |
Type |
A/B |
A/B |
A/B |