Electrical supply, EB/ES
Contents

C4 EB (three-phase FC)

C4 ES (three-phase FC)

C4 EB (single-phase FC)

C4 ES (single-phase FC)

C4 EB (three-phase FC)

 

 

12.20

20.10

20.20

3~ 400V 50/60Hz

 

 

 

Rated power consumption

[kW]

33.7

38.9

67.3

Convection power

[kW]

33.3

38.1

66.5

Steam power

[kW]

31.6

31.6

40.2

Motor power

[kW]

0.35

0.7

0.7

Rated current

[A]

48.7

56.2

97.3

Fuse rating

[A]

50

63

100

Residual current

[mA]

-

-

-

Protective earth current

[mA]

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G16

5G16

5G35

Residual-current device

Type

B

B

B

C4 ES (three-phase FC)

 

 

12.20

20.10

20.20

3~ 400V 50/60Hz

 

 

 

Rated power consumption

[kW]

33.7

38.9

67.3

Convection power

[kW]

33.3

38.1

66.5

Motor power

[kW]

0.35

0.7

0.7

Rated current

[A]

48.7

56.2

97.3

Fuse rating

[A]

50

63

100

Residual current

[mA]

-

-

-

Protective earth current

[mA]

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G16

5G16

5G35

Residual-current device

Type

B

B

B

C4 EB (single-phase FC)

 

 

12.20

20.10

20.20

3N~ 400V 50/60Hz (3/N/PE)

 

 

 

Rated power consumption

[kW]

33.7

38.9

67.3

Convection power

[kW]

33.3

38.1

66.5

Steam power

[kW]

31.6

31.6

40.2

Motor power

[kW]

0.35

0.7

0.7

Rated current

[A]

48.7

56.2

97.3

Fuse rating

[A]

50

63

100

Residual current

[mA]

~7.5

~16.5

~16.5

Protective earth current

[mA]

~7.5

~16.5

~16.5

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G16

5G16

5G35

Residual-current device

Type

A/B

A/B

A/B

3~ 230V 50/60Hz (3/PE)

 

 

 

Rated power consumption

[kW]

33.4

38.2

66.4

Convection power

[kW]

33.0

37.8

66.0

Steam power

[kW]

31.3

31.3

39.9

Motor power

[kW]

0.35

0.7

0.7

Rated current

[A]

84.0

96.0

166.9

Fuse rating

[A]

100

100

200

Residual current

[mA]

-

-

-

Protective earth current

[mA]

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G35

4G35

4G70

Residual-current device

Type

A/B

A/B

A/B

C4 ES (single-phase FC)

 

 

12.20

20.10

20.20

3N~ 400V 50/60Hz (3/N/PE)

 

 

 

Rated power consumption

[kW]

33.7

38.9

67.3

Convection power

[kW]

33.3

38.1

66.5

Motor power

[kW]

0.35

0.7

0.7

Rated current

[A]

48.7

56.2

97.3

Fuse rating

[A]

50

63

100

Residual current

[mA]

~7.5

~16.5

~16.5

Protective earth current

[mA]

~7.5

~16.5

~16.5

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G16

5G16

5G35

Residual-current device

Type

A/B

A/B

A/B

3~ 230V 50/60Hz (3/PE)

 

 

 

Rated power consumption

[kW]

33.4

38.2

66.4

Convection power

[kW]

33.0

37.8

66.0

Motor power

[kW]

0.35

0.7

0.7

Rated current

[A]

84.0

96.0

166.9

Fuse rating

[A]

100

100

200

Residual current

[mA]

-

-

-

Protective earth current

[mA]

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G35

4G35

4G70

Residual-current device

Type

A/B

A/B

A/B


Up