Electrical supply, marine
Contents

C4 EB (three-phase FC)

C4 ES (three-phase FC)

C4 EB (three-phase FC)

 

 

6.10

6.20

10.10

10.20

3~ 440V 50/60Hz

 

 

 

 

Rated power consumption

[kW]

9.2

16.3

16.3

28.2

Convection power

[kW]

8.8

15.9

15.9

27.8

Steam power

[kW]

7.6

15.1

15.1

22.7

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

12.1

21.4

21.4

37.0

Fuse rating

[A]

16

25

25

50

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G4

4G6

4G6

4G16

Residual-current device

Type

B

B

B

B

3~ 480V 50/60Hz

 

 

 

 

Rated power consumption

[kW]

10.9

19.3

19.3

33.4

Convection power

[kW]

10.5

18.9

18.9

33.0

Steam power

[kW]

9.0

18.0

18.0

27.0

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

13.1

23.3

23.3

40.3

Fuse rating

[A]

16

25

25

50

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G4

4G6

4G6

4G16

Residual-current device

Type

B

B

B

B

C4 ES (three-phase FC)

 

 

6.10

6.20

10.10

10.20

3~ 440V 50/60Hz

 

 

 

 

Rated power consumption

[kW]

9.2

16.3

16.3

28.2

Convection power

[kW]

8.8

15.9

15.9

27.8

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

12.1

21.4

21.4

37.0

Fuse rating

[A]

16

25

25

50

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G4

4G6

4G6

4G16

Residual-current device

Type

B

B

B

B

3~ 480V 50/60Hz

 

 

 

 

Rated power consumption

[kW]

10.9

19.3

19.3

33.4

Convection power

[kW]

10.5

18.9

18.9

33.0

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

13.1

23.3

23.3

40.3

Fuse rating

[A]

16

25

25

50

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G4

4G6

4G6

4G16

Residual-current device

Type

B

B

B

B