Electrical supply, Mexico/Nicaragua
Contents

C4 GB (single-phase FC)

C4 GS (single-phase FC)

C4 GB (single-phase FC)

 

 

6.10

6.20

10.10

10.20

1N~ 120V 60Hz

 

 

 

 

Rated power consumption

[kW]

0.6

0.6

0.6

0.6

Convection power

[kW]

0.1

0.1

0.1

0.1

Steam power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.4

0.4

0.4

0.4

Rated current

[A]

5.7

5.7

5.7

5.7

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

2.4

-

10.6

-

Protective earth current

[mA]

-

-

1.6

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B

2~ 230 V 50/60Hz

 

 

 

 

Rated power consumption

[kW]

0.6

0.6

0.6

0.6

Convection power

[kW]

0.1

0.1

0.1

0.1

Steam power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

2.7

2.7

2.7

2.7

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

7.9

-

7.5

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B

C4 GS (single-phase FC)

 

 

6.10

6.20

10.10

10.20

1N~ 120V 60Hz

 

 

 

 

Rated power consumption

[kW]

0.5

0.5

0.5

0.5

Convection power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.4

0.4

0.4

0.4

Rated current

[A]

4.7

4.7

4.7

4.7

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

2.0

5.7

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B

2~ 230 V 50/60Hz

 

 

 

 

Rated power consumption

[kW]

0.6

0.6

0.6

0.6

Convection power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

2.7

2.7

2.7

2.7

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

7.0

7.0

7.6

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B


Up