Contents |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
3~ 200 V 50/60 Hz (3/PE) |
|
|
|
|
|
Rated power consumption |
[kW] |
10.9 |
19.3 |
19.3 |
33.4 |
Convection power |
[kW] |
10.5 |
18.9 |
18.9 |
33.0 |
Steam power |
[kW] |
9.0 |
18.0 |
18.0 |
27.0 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
31.5 |
55.8 |
55.8 |
96.6 |
Fuse rating |
[A] |
35 |
63 |
63 |
100 |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G6 |
4G16 |
4G16 |
4G35 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
A/B |
|
|
6.10 |
6.20 |
10.10 |
10.20 |
3~ 200 V 50/60 Hz (3/PE) |
|
|
|
|
|
Rated power consumption |
[kW] |
10.9 |
19.3 |
19.3 |
33.4 |
Convection power |
[kW] |
10.5 |
18.9 |
18.9 |
33.0 |
Motor power |
[kW] |
0.35 |
0.35 |
0.35 |
0.35 |
Rated current |
[A] |
31.5 |
55.8 |
55.8 |
96.6 |
Fuse rating |
[A] |
35 |
63 |
63 |
100 |
Residual current |
[mA] |
- |
- |
- |
- |
Protective earth current |
[mA] |
- |
- |
- |
- |
Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length. |
[mm2] |
4G6 |
4G16 |
4G16 |
4G35 |
Residual-current device |
Type |
A/B |
A/B |
A/B |
A/B |