Electrical supply, Japan
Contents

C4 EB (single-phase FC)

C4 ES (single-phase FC)

C4 EB (single-phase FC)

 

 

6.10

6.20

10.10

10.20

3~ 200 V 50/60 Hz (3/PE)

 

 

 

 

Rated power consumption

[kW]

10.9

19.3

19.3

33.4

Convection power

[kW]

10.5

18.9

18.9

33.0

Steam power

[kW]

9.0

18.0

18.0

27.0

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

31.5

55.8

55.8

96.6

Fuse rating

[A]

35

63

63

100

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G6

4G16

4G16

4G35

Residual-current device

Type

A/B

A/B

A/B

A/B

C4 ES (single-phase FC)

 

 

6.10

6.20

10.10

10.20

3~ 200 V 50/60 Hz (3/PE)

 

 

 

 

Rated power consumption

[kW]

10.9

19.3

19.3

33.4

Convection power

[kW]

10.5

18.9

18.9

33.0

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

31.5

55.8

55.8

96.6

Fuse rating

[A]

35

63

63

100

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G6

4G16

4G16

4G35

Residual-current device

Type

A/B

A/B

A/B

A/B


Up