Electrical supply, Korea
Contents

C4 EB/ES (single-phase FC)

C4 GB (single-phase FC)

C4 GS (single-phase FC)

C4 EB/ES (single-phase FC)

 

 

6.10

6.20

10.10

10.20

3~ 220 V 60 Hz (3/PE)

 

 

 

 

Rated power consumption

[kW]

10.2

17.7

17.7

30.6

Convection power

[kW]

9.6

17.3

17.3

30.2

Steam power (EB only)

[kW]

8.2

16.5

16.5

24.7

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

26.8

 

46.5

46.5

80.3

Fuse rating

[A]

35

50

50

100

Residual current

[mA]

-

-

-

-

Protective earth current

[mA]

-

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

4G6

4G10

4G16

4G35

Residual-current device

Type

A/B

A/B

A/B

A/B

3N~ 380 V 60 Hz (3/N/PE)

 

 

 

 

Rated power consumption

[kW]

10.1

17.6

17.6

30.5

Convection power

[kW]

9.6

17.2

17.2

30.1

Steam power (EB only)

[kW]

8.2

16.3

16.3

24.5

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

15.4

26.7

26.7

46.3

Fuse rating

[A]

16

32

32

50

Residual current

[mA]

~7.5

~7.5

~7.5

~7.5

Protective earth current

[mA]

~7.5

~7.5

~7.5

~7.5

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

5G4

5G6

5G6

5G16

Residual-current device

Type

A/B

A/B

A/B

A/B

C4 GB (single-phase FC)

 

 

6.10

6.20

10.10

10.20

1N~ 220V 60Hz (1/N/PE)

 

 

 

 

Rated power consumption

[kW]

0.6

0.6

0.6

0.6

Convection power

[kW]

0.1

0.1

0.1

0.1

Steam power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

2.7

2.7

2.7

2.7

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

7.9

-

-

-

Protective earth current

[mA]

28.0

-

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B

C4 GS (single-phase FC)

 

 

6.10

6.20

10.10

10.20

1N~ 220V 60Hz (1/N/PE)

 

 

 

 

Rated power consumption

[kW]

0.5

0.5

0.5

0.5

Convection power

[kW]

0.1

0.1

0.1

0.1

Motor power

[kW]

0.35

0.35

0.35

0.35

Rated current

[A]

2.3

2.3

2.3

2.3

Fuse rating

[A]

16

16

16

16

Residual current

[mA]

7.0

7.0

6.9

-

Protective earth current

[mA]

28.0

33.0

-

-

Recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.

[mm2]

3G2.5

3G2.5

3G2.5

3G2.5

Residual-current device

Type

A/B

A/B

A/B

A/B